Page 193 - Demo
P. 193


                                    Animal experiment: Radiological analysis of the LPM reattachment1917laterally from the implant and appeared to connect the mandible to the skull base. A fracture of this heterotopic bone prevented joint ankylosis. This fracture was likely due to continued movement of the mandible. One of the two sheep scanned at 6 months after surgery, # 2177, had a bony connection between the enthesis and the mandible, as was found in the previous two sheep. However, there was no bony connection between the enthesis and the scaffold. There was heterotopic bone formation around the lateral side of both the ramal and the fossa components. There was also a slight latero-inferior displacement of the fossa component, showing non-integration onto the articular tubercle. The scan of the second sheep, ewe 2549, revealed good positioning of both TMJR components, but there was no enthesis reconstruction with osseous or fibrotic characteristics. Table 3: Type of connection formed post-mortem between the mandible and lateral pterygoid muscle (LPM), based on CT evaluationSheep # Connection type3520 Soft tissue connection between the implant scaffold and reattached enthesisBony connection between the mandible and reattached enthesis8087 Bony connection between the implant scaffold and reattached enthesisBony connection between the mandible and reattached enthesis2177 Boney connection between the mandible and reattached enthesis5158 Partial bony and soft tissue connection between the implant scaffold and reattached enthesisBony connection between the mandible and reattached enthesis2549 Absent4249 Bony connection between the implant scaffold and reattached enthesisBony connection between the mandible and reattached enthesis0032 Soft tissue connection between the implant scaffold and reattached enthesisBony connection between the mandible and reattached enthesis7998 Bony connection between the mandible and reattached enthesis4246 Partial bony and soft tissue connection between the implant scaffold and reattached enthesisBony connection between the mandible and reattached enthesis 1724 Soft tissue connection between the implant scaffold and reattached enthesisBony connection between the mandible and reattached enthesis4248 Partial bony and soft tissue connection between the implant scaffold and reattached enthesisBony connection between the mandible and reattached enthesis8787 Absent4473 *Absent0075 SHAM* Due to dissectionNikolas de Meurechy NW.indd 191 05-06-2024 10:14
                                
   187   188   189   190   191   192   193   194   195   196   197