Page 160 - Demo
P. 160
Chapter 515818. Almarza AJ, Brown BN, Arzi B, Ângelo DF, Chung W, Badylak SF, et al. Preclinical Animal Models for Temporomandibular Joint Tissue Engineering. Tissue Eng Part B Rev. 2018 Jun;24(3):171–8. 19. Domingue BM, Dellow DW, Barry TN. The efficiency of chewing during eating and ruminating in goats and sheep. Br J Nutr. 1991 May;65(3):355–63. 20. Mommaerts MY. On the reinsertion of the lateral pterygoid tendon in total temporomandibular joint replacement surgery. J Cranio-Maxillo-Facial Surg [Internet]. 2019;47(12):1913–7. Available from: https://doi.org/10.1016/j.jcms.2019.11.01821. Singh R, Dahotre NB. Corrosion degradation and prevention by surface modification of biometallic materials. J Mater Sci Mater Med. 2007;18(5):725–51. 22. Bracco P, Oral E. Vitamin E-stabilized UHMWPE for total joint implants: A review. Clin Orthop Relat Res. 2011;469(8):2286–93. 23. Wolf C, Lederer K, Muller U. Tests of biocompatibility of alpha-tocopherol with respect to the use as a stabilizer in ultrahigh molecular weight polyethylene for articulating surfaces in joint endoprostheses. J Mater Sci Mater Med. 2002 Jul;13(7):701–5. 24. De Meurechy N, Verwilghen D, De Brucker Y, Van Thielen B, Mommaerts MY. Lateral pterygoid muscle enthesis reconstruction in total temporomandibular joint replacement: An animal experiment with radiological correlation. J Cranio-Maxillofacial Surg. 2021 Feb;49(4):256–68. 25. Verplancke K, De Waele W, De Bruyn H. Dental implants, what should be known before starting an in vitro study. Conf Sustain Constr Des [Internet]. 2011;2(3):360–9. Available from: https://biblio.ugent.be/publication/117703026. Selvik G. Roentgen stereophotogrammetric analysis. Acta Radiol. 1990 Mar;31(2):113–26. 27. Dumbleton JH, Manley MT, Edidin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty. 2002 Aug;17(5):649–61. 28. Oparaugo PC, Clarke IC, Malchau H, Herberts P. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature. Acta Orthop Scand. 2001 Feb;72(1):22–8. 29. Benjamin J, Szivek J, Dersam G, Persselin S, Johnson R. Linear and Volumetric Wear of Tibial Inserts in Posterior Cruciate-Retaining Knee Arthroplasties. 2001;(392):131–8. 30. Chaudhary N, Lovald ST, Wagner J, Khraishi T, Baack B. Experimental and Numerical Modeling of Screws Used for Rigid Internal Fixation of Mandibular Fractures. Model Simul Eng [Internet]. 2008 Jan;2008. Available from: https://doi.org/10.1155/2008/62812031. Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2003;18(3):357–68. 32. Skinner R, Maybee J, Transfeldt E, Venter R, Chalmers W. Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study. Spine (Phila Pa 1976). 1990 Mar;15(3):195–201. 33. Wang A, Polineni VK, Stark C, Dumbleton JH. Effect of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene acetabular cups. J Arthroplasty [Internet]. 1998;13(6):615–20. Available from: http://www.sciencedirect.com/science/article/pii/S088354039880002834. Jedenmalm A, Affatato S, Taddei P, Leardini W, Gedde UW, Fagnano C, et al. Effect of head surface roughness and sterilization on wear of UHMWPE acetabular cups. J Biomed Mater Res A. 2009 Sep;90(4):1032–42. 35. Tubb CC, Longaray JA, Herrera L, Essner AP, Molloy RM. The Effect of Femoral Component Roughness on the Wear of Total Knee Implants. Orthop Res Soc. 2011;36. 36. McGloughlin TM, Kavanagh AG. Wear of ultra-high molecular weight polyethylene (UHMWPE) in total knee prostheses: a review of key influences. Proc Inst Mech Eng Part H, J Eng Med. 2000;214(4):349–59. 37. Jiang SW, Jiang B, Li Y, Li YR, Yin GF, Zheng CQ. Friction and wear study of diamond-like carbon gradient coatings on Ti6Al4V substrate prepared by plasma source ion implant-ion beam enhanced deposition. Appl Surf Sci. 2004;236(1):285–91. Nikolas de Meurechy NW.indd 158 05-06-2024 10:14