Page 220 - Prevention and Treatment of Incisional Hernia- New Techniques and Materials
P. 220

Chapter 10
Figure 3. Percentage of the mesh edge incorporated into the abdominal wall. At 30 days, no signi cant di erences were found. Values are median (interquartile range). §p < 0.050 versus Prolene, Strattice, and Permacol. For each mesh, no signi cant di erences were observed between 30 and 90 days (Mann– Whitney U test).
Figure 4. Shrinkage of the mesh surface compared with the original size. At 30 days: §p < 0.050 versus all other meshes; ±p < 0.050 versus Permacol and Strattice. At 90 days: *p < 0.050 versus all other meshes; ¶p < 0.050 versus Prolene. Compared with 30 days, Surgisis, Parietex composite, and Strattice showed signi cant more shrinkage (Mann–Whitney U test)
Tenacity of adhesions
At 30 days, the Zühlke score for adhesions to the Permacol mesh was signi cantly higher than the score for Prolene (p = 0.011), Parietex composite (p = 0.004), or
218


































































































   218   219   220   221   222