Page 90 - Craniomaxillofacial Implant Surgery - Jeroen P.J. Dings
P. 90
Chapter 5
88
Table 2.Influence of retentive mechanisms and anatomic location on psychological and social aspect
Orbital prostheses Nasal prostheses
Auricular prostheses (23 patients)
Total prostheses (n=52)
I don’t regard my prosthesis as part of myself (no. of patients)
1 (8)
3
Negative influence on mood Negative influence on leisure Negative influence on school/work Negative influence on social activities Negative influence on sexual activity Others notice my prosthesis
1 - - 1 - 2 - 2
1 - - - - 4 - 3
1 2 - - - 1 - 1
3 (25) 2 (17) 0 (0) 1 (8) 0 (0) 7 (58) 0 (0) 6 (50)
2 3 - 2 1 7 1 3
1 - - - - 4 - 2
1 - 1 - 1 1 1 1
4 (24) 3 (18) 1 (6) 2 (12) 2 (12) 12 (71) 2 (12) 6 (35)
3 3 - 2 - 2 - 8
1 - - - - - 1 -
2 2 1 2 - 4 - 3
6 (26) 5 (22) 1 (4) 4 (17) 0 (0) 6 (26) 1 (4) 11 (48)
13 (25) 10 (19) 2 (4) 7 (14) 2 (4) 25 (48) 3 (6) 23 (44)
I am embarrassed by my prosthesis
My self-esteem is improved by my prosthesis
(12 patients) (17 patients)
Bar-clip Magnet Adhesive Total Bar-clip Magnet Adhesive Total
Bar-clip Magnet Adhesive Total
( 3 pt.) n
-
(7 pt.) n
1
(2 pt.) n
-
(12 pt.) (8 pt.) n (%) n
(6 pt.) n
-
(3 pt.) n
1
(17 pt) n (%) 4 (23)
(12 pt.) n
-
(2 pt.) n
1
(9 pt.) n
2
(23 pt.) n (%) 3 (13)
n (%) 8 (15)
Table 3. Rating of general satisfaction of prostheses on different anatomical locations having different retentive mechanisms
Score (0-10)
Score implant-retained prostheses
Bar-clip (n=3)
Magnet (n=7)
Adhesive (n=2)
Bar-clip (n=8)
Magnet (n=6)
Adhesive (n=3)
Bar-clip (n=12)
Magnet (n=2)
Adhesive (n=9)
Score previous prostheses with adhesive attachment
n=1
n=4
n=0
n=4
n=3
n=0
n=2
n=1
n=0
9.7 (SD 0.6)
8.0 (SD 1.2)
7.0 (SD 1.4)
7.7 (SD 2.3)
7.8 (SD 1.2)
6.5 (SD 2.1)
8.9 (SD 0.8)
8.5 (SD 0.7)
8.3 (SD 1.4)
Orbital prostheses
Nasal prostheses
Auricular prostheses
0.0 3.0 - 5.5 4.7 - 8.0 1.0 - (SD 1.8) (SD 0.6) (SD 1.5) (SD 0.0)